Next-Gen Modular Spectroscopy
See the
unseen.
Spectroa engineers ultra-compact, high-resolution spectrometers that move precision analytics from the optical table to the field. Covering UV to NIR with sub-nanometer resolution.
Resolution
<0.1nm
Spectral Range
190-2500nm
Stray Light
<0.05%
Integration Time
1ms
The Spectroa Thesis
Dr. Elena Rostova
Chief Optical Engineer
For decades, obtaining lab-grade spectral data meant bringing the sample to the lab, compromising on either speed or sample integrity. We rejected the premise that high-resolution optics necessitate bulky desktop footprints.
By rethinking the optical bench architecture—specifically employing symmetric crossed Czerny-Turner designs paired with ultra-low thermal expansion materials—we have minimized spherical aberration and coma without expanding the physical path length.
The result is a class of instruments that deliver sub-nanometer resolution in a form factor small enough to integrate directly into manufacturing lines or field diagnostic kits.
Precision in Every Component
We don't off-the-shelf our critical path. From the entrance slit to the focal plane, every element is specified and verified in-house.
Photolithographic Slits
Etched in stainless steel with 1μm tolerance, defining exact optical resolution and throughput.
Toroidal Mirrors
Correcting for astigmatism inherent in short focal length systems, keeping focal planes perfectly flat.
Holographic Gratings
Blazed for specific UV, VIS, or NIR regions to maximize efficiency and virtually eliminate ghosting.
TE-Cooled Arrays
Suppressing dark noise by operating detectors at -15°C relative to ambient for long integration times.
Instrument Series
View full specsSP-Series
Photon-UV
190nm – 400nm
- Back-thinned CCD
- Enhanced UV response
- 0.2nm Resolution
SR-Series
Spectra-VIS
350nm – 1050nm
- 2048-pixel CMOS
- High Dynamic Range
- 0.3nm Resolution
Uncompromising Signal Integrity
A spectrometer is only as good as its stray light rejection. Our proprietary light baffles and blazed holographic gratings achieve stray light levels typically reserved for double-monochromator setups.
Out of the Lab. Into the Process.
Process Analytical Technology (PAT)
Integrating inline spectroscopy directly into chemical synthesis flows reduces sampling delay to zero. Our OEM modules are designed for direct flange mounting, featuring robust SMA 905 fiber connectors and vibration-damped optical benches.
Request OEM integration guideSupported Protocols
- > USB 3.0 / Gigabit Ethernet
- > RS-232 / RS-485 Modbus
- > 4-20mA Analog Out
- > Native DLL & Python SDK
Engineered for Specific Environments
Material Science
Characterize thin films, measure transmission properties, and verify chemical composition of polymers on the manufacturing floor.
- > Reflectance monitoring
- > Colorimetry (L*a*b*)
- > Raman identification
Life Sciences
Quantify DNA/RNA concentrations, monitor cell cultures, and perform non-destructive tissue analysis with sterile-compatible probes.
- > Micro-volume absorbance
- > Fluorescence kinetics
- > Protein assay quantification
Environmental
Deploy remote sensing units for water quality monitoring, atmospheric gas analysis, and agricultural health index mapping.
- > Nitrates & Phosphates (UV)
- > Soil moisture (NIR)
- > Solar irradiance
Data Without Friction
We don't believe in proprietary file formats. Our SDK provides direct access to raw uncalibrated sensor data, dark-corrected spectra, or fully linearized transmission data via standard JSON structures or rapid byte streams.
- ✓ Python & C++ libraries
- ✓ LabVIEW VIs available
- ✓ Zero mandatory cloud connectivity
import spectroa
# Initialize SR-Series bench
device = spectroa.connect(model="SR-VIS")
device.set_integration_time(ms=10)
# Acquire spectrum with automatic dark subtraction
spectrum = device.acquire(dark_subtract=True)
# Output wavelength and intensity pairs
for w, i in zip(spectrum.wavelengths, spectrum.intensities):
if w > 500 and w < 510:
print(f"{w:.2f} nm : {i:.4f} a.u.")
NIST-Traceable
Rigorous Calibration Methodology
Every spectrometer undergoes a 48-hour thermal cycling procedure before calibration against Hg-Ar and Ne emission lines. We guarantee wavelength accuracy within 0.1nm across the specified operating temperature range.
Read our calibration standardsCited in recent literature
J. Phys. Chem. Lett. (2023)
"In-situ monitoring of perovskite crystallization kinetics using a high-speed fiber-coupled Czerny-Turner spectrometer..."
Using Spectroa SP-UV
Anal. Chem. (2024)
"Trace detection of organophosphates via surface-enhanced Raman scattering (SERS) employing a compact 785nm excitation module..."
Using Spectroa SN-NIR
Environ. Sci. Technol. (2023)
"Autonomous marine buoys equipped with sub-nanometer resolution spectrometers for real-time CDOM quantification..."
Using Spectroa SR-VIS
Frequently Asked Engineering Questions
Open Optical Calculators
We believe in providing the tools necessary for proper experimental design. Access our suite of free, no-JS fallback calculators for everyday optical mathematics.
Technical Bulletins
Receive application notes, SDK updates, and new hardware specifications. No marketing fluff.
Ready to configure your bench?
Speak directly with an application scientist. No sales reps. Just engineers solving optical problems.